63 VA2.62 A at 24 V

  • —
  • —
  • 2-year warranty · wound and tested in Gailhan

Key features

This 230V to 24V transformer steps the 230 V single-phase mains — formerly 220 V — down to 24 volts AC, the extra-low voltage used for automation, control and lighting: gate motors, irrigation solenoid valves, relays and contactors, electric door strikes, halogen lamps. The primary and secondary are two separate windings. From 63 VA to 20 kVA, open frame (IP00), with a ventilated cover (IP23) or in a sealed housing (IP54): it is wound and tested in our workshop in Gailhan, in the Gard (southern France).

Your supply230 V ~single-phase, formerly 220 V
Transformer230 → 24 Visolates and steps down
Your equipment24 V ~AC: gates, solenoid valves, control, halogen lamps
24 V ACThe voltage for automation, control circuits and low-voltage lighting.
Two separate windingsNo electrical connection between the 230 V and the 24 V.
Screw terminals up to 55 A, lugs aboveScrew terminals up to 1 kVA on this model, lugs above that. Terminal marking: 1 and 2 on the primary (0 and 230 V), 3 and 4 on the secondary (0 and 24 V), earth on the primary side.
Open frame, covered or sealedIP00 for cabinet mounting, IP23 with a ventilated cover, IP54 in a moulded housing or a sealed enclosure.
100 % testedEvery transformer is tested before it leaves the workshop.
Made in GailhanWound, wired and inspected in our workshop in the Gard, southern France.
220 V or 230 V: the same mains supply

220 V is the former name for 230 V. A 220V to 24V transformer connects to the same mains and gives the same 24 V.

At 24 V, cable length matters

The current is almost ten times higher than at 230 V: over 25 m, 10 A already needs 10 mm² cable. Work out the cable size before you run the cable.

Off load, you will measure slightly more than 24 V

That is normal: about 25.4 V off load on the 63 VA, 24.7 V on the 1,000 VA. The voltage falls to 24 V at full load.

When should you use a 24V transformer?

  • 24 V AC motors for gates, garage doors and roller shutters.
  • Solenoid valves and automatic irrigation controllers.
  • Control circuits: relay and contactor coils, industrial solenoid valves.
  • Electric door strikes, intercoms, doorbells and alarm panels.
  • Low-voltage lighting: 24 V halogen lamps, lighting for fairground rides and stalls.
  • Test benches and machines that need an AC extra-low voltage.

It works on 50 and 60 Hz supplies and delivers AC: for 24 V DC, see the next section.

24 V AC or 24 V DC?

Check the rating plate on your device. The marking tells you which product you need.

24 V AC, 24 VAC or 24 V ~ → this transformer24 V DC, 24 VDC or 24 V ⎓ → a power supply
24 V alternating current · AC · ~This transformer
  • 24 V AC gate and roller shutter motors
  • Irrigation solenoid valves
  • 24 V AC relay and contactor coils
  • 24 V halogen lamps
  • 24 V AC door strikes, doorbells and intercoms
Choose your rating

Specifications of the 230 V / 24 V transformer

Values for the selected configuration: 63 VA · IP00.

Rating63 VA50 / 60 Hz
Primary230 V ~0.27 A
Secondary24 V ~2.62 A
ProtectionIP00Open frame, for cabinet mounting
Primary
Voltage
230 V AC (formerly 220 V)
Rated current
—
Terminals
1 (0 V) · 2 (230 V) · earth
Recommended protection
—
Secondary
On-load voltage
24 V AC
No-load voltage
—
Rated current
—
Terminals
3 (0 V) · 4 (24 V)
Recommended protection
—
Construction
Type
Dry-type transformer, two separate windings
Core
EI laminations, flux density 1.2 T
Insulation class
H (180 °C)
Temperature rise
50 °C, 40 °C maximum ambient
Standards
EN 61558-2-4 and EN 61558-2-6
Thermal protection
On request
Enclosure
IP rating
—
Overall dimensions L × W × H
—
Weight
—
Mounting
—
Altitude
3,000 m maximum
Connection
Screw terminals up to 55 A (1 kVA on this model), lugs above
Performancedesign values
Full-load efficiency—
No-load losses—
Load losses—
Full-load voltage drop—

Ratings and prices

From 63 VA to 20 kVA. Above that, or for another voltage, on request.

W × 1.25 = 250 VA → recommended 250 VA
Rating24 V currentPrimary fuse24 V protectionNo-load / load lossesEfficiencyWeightDimensions (mm)Price ex VAT
63 VA2.6 AaM 2 AaM 4 A2 / 3.4 W92.1 %1.5 kg75 × 68 × 73€47.42
100 VA4.2 AaM 2 AaM 6 A3 / 5.3 W92.0 %2 kg84 × 82 × 78€57.42
160 VA6.7 AaM 2 AaM 8 A4 / 8.6 W91.9 %2.5 kg96 × 89 × 87€63.25
200 VA8.3 AaM 2 AaM 10 A5 / 9.1 W93.0 %2.6 kg118 × 97 × 97€66.58
250 VA10.4 AaM 2 AaM 12 A6 / 10.2 W93.6 %3.9 kg108 × 95 × 100€78.25
300 VA12.5 AaM 2 AaM 16 A6 / 14.9 W93.0 %4 kg108 × 103 × 94€80.75
400 VA16.7 AaM 2 AaM 20 A8 / 15 W94.2 %6 kg126 × 122 × 108€102.42
500 VA20.8 AaM 4 AaM 25 A10 / 18.4 W94.4 %6.8 kg126 × 110 × 115€112.42
630 VA26.2 AaM 4 AaM 32 A11 / 24.5 W94.3 %9 kg150 × 124 × 126€132.42
750 VA31.2 AaM 4 AaM 40 A15 / 23.6 W94.8 %10.3 kg150 × 120 × 135€144.92
1 kVA41.7 AaM 6 AaM 50 A18 / 29 W95.3 %14 kg150 × 144 × 127€175.75
1.6 kVA66.7 AaM 8 AaM 80 A19 / 46.9 W95.9 %16.4 kg180 × 140 × 160€219.92
2 kVA83.3 AaM 10 AaM 100 A19 / 60.3 W96.0 %20 kg180 × 160 × 160€243.25
2.5 kVA104.2 AaM 12 AaM 125 A24 / 67.6 W96.3 %24 kg180 × 180 × 150€250.75
3 kVA125.0 AaM 16 AaM 160 A37 / 81.3 W96.1 %29 kg180 × 200 × 160€288.25
4 kVA166.7 AaM 20 AaM 200 A42 / 103.8 W96.3 %33 kg240 × 190 × 220€425.75
5 kVA208.3 AaM 25 AaM 250 A45 / 121.3 W96.7 %36 kg240 × 200 × 220€458.25
6.3 kVA262.5 AaM 32 AaM 315 A56 / 130.3 W97.0 %40 kg240 × 210 × 220€483.25
7.5 kVA312.5 AaM 40 AaM 400 A56 / 160 W97.1 %46 kg240 × 230 × 220€548.25
10 kVA416.7 AaM 50 AaM 500 A—*—*75 kg390 × 150 × 470€1,012.42
15 kVA625.0 AaM 80 AaM 800 A—*—*80 kg390 × 160 × 470€1,145.75
20 kVA833.3 AaM 100 AaM 1000 A—*—*95 kg390 × 170 × 470€1,279.92

aM fuses sized for the rated current; alternatively, a type D circuit breaker of the same rating. * 10 to 20 kVA: catalogue weights and dimensions, losses on request.

Cable size on the 24 V side

Voltage drop depends on the current and the length. Aim for less than 5 % (3 % for lighting).

A
m
The calculation allows for both the outgoing and return conductors.
Application
Recommended cable size——
Cable sizeDropVoltage at the deviceDrop (%)Verdict

Copper cable, resistivity 0.0225 Ω·mm²/m (at operating temperature), outgoing and return conductors, reactance ignored. “Too small for this current”: current-carrying capacity of a PVC-insulated copper cable in conduit, two loaded conductors, for guidance only. Final sizing is the installer's responsibility (IEC 60364; NF C 15-100 in France).

Connection and dimensions

Extracts from the datasheet: diagram, terminal block and dimensions.

Connection diagram
PRIMARYSECONDARYMagnetic corePrimary 1 · 230 V10 V2230 VSecondary 1 · 24 V · 63 VA30 V424 V
P10 V1230 V2S10 V324 V4
Dimensioned drawing
Technical document for the TMN23024 series
PDF · specifications, ratings and part numbers, protection
FRENDEESIT

Primary protection

—

—

24 V protection

—

As close as possible to the transformer, on the 24 V outgoing circuit.

Safety

  • Connection with the power off, by a qualified person.
  • Earth connected before switching on.
  • IP00: inside a closed cabinet or enclosure.

Standards, warranty and options

A standard transformer, made in Gailhan and also available in other voltages.

EN 61558-2-4 and -2-6with Part 1: isolation and safety (SELV)
CE markingLow Voltage, EMC
RoHSfree of lead and restricted substances
2-year warrantyon this transformer
Made in FranceGailhan workshop (Gard, southern France)
Parcel or palletpallet over 30 kg
Other voltages12 V, 48 V, 400 V → 24 V
EnclosuresIP23 cover, IP54 moulded housing or enclosure

Frequently asked questions

About the 230 V / 24 V single-phase transformer.

Does this 230V to 24V transformer supply DC?

No: it supplies 24 V AC. For 24 V DC, choose a 230 V / 24 V DC power supply (motors, door strikes, batteries) or a 24 V LED power supply (LED strips, electronics).

220V to 24V or 230V to 24V transformer: what is the difference?

None: 220 V is the former name for the 230 V mains. A 220V to 24V transformer connects to the same mains and gives the same 24 V.

Which rating should I choose?

Add up the power of the equipment supplied at 24 V, multiply by 1.25 and take the next rating up: a 200 W gate motor needs 250 VA; 1,200 W of equipment needs 1,500 VA, so a 1.6 kVA transformer. The calculator above the table does this for you.

Why do I measure more than 24 V?

Off load, the voltage is slightly higher: about 25.4 V on the 63 VA and 24.7 V on the 1,000 VA. It falls to 24 V when the transformer delivers its rated current. Measure with your multimeter set to AC (V~).

What cable size on the secondary?

It depends on the current and the length: at 24 V, a 1 V drop is already 4 %. For example, 10 A over 25 m needs 10 mm² cable to stay below 5 %. The cable size calculator works it out for your installation.

How do I connect a 230V to 24V transformer?

The 230 V supply goes to terminals 1 (0 V) and 2 (230 V), and earth to the primary earth terminal; your 24 V equipment is fed from terminals 3 (0 V) and 4 (24 V). The connection diagram is on the datasheet.

What protection should I install?

On the primary, an aM fuse or a type D circuit breaker rated for the primary current: 2 A for the 63 VA, 6 A for the 1,000 VA. On the secondary, protection rated for the 24 V current: a 4 A aM fuse for the 63 VA, 50 A for the 1,000 VA. At switch-on, the transformer draws about twelve times its rated current; the protection rating for each size is given in the table.

Can it be used in reverse, from 24 V to 230 V?

Not from a battery: a battery supplies DC, which a transformer cannot step up. You need a converter, also called an inverter. For any other case, tell us what you need.

IP00, IP23 or IP54: which should I choose?

IP00: open-frame transformer, to be installed in a cabinet or enclosure. IP23: ventilated cover, for a dry room. IP54: moulded housing up to 630 VA, sealed enclosure above that, protected against dust and splashing water, for sheltered outdoor use.

Is it suitable for fairgrounds and safety extra-low voltage?

Safety extra-low voltage (SELV), required for example on fairground rides and in damp locations, calls for a safety isolating transformer complying with EN 61558-2-6: this 230 V / 24 V transformer meets that requirement, as it complies with the current standards (EN 61558-2-4 and EN 61558-2-6).

Customer reviews

Reviews posted by customers who bought this transformer (in French).

4.9
11 reviews · 10 five-star
Bastien Leroux · 27 novembre 2025

Produit livré rapidement, bien emballé. Installation facile. Le transfo fonctionne sans bruit et la tension reste stable. Fabrication soignée, on sent la qualité française. Très satisfait de mon achat.

Céline Moretti · 10 décembre 2025

Produit conforme, installation sans surprise, fait très bien son boulot pour la sécurité de mon portail. Livraison rapide, bien emballé. Fabrication française appréciée.

Laurent Maes · 15 décembre 2025

reçu en 24h c'est du sérieux!!!

Xavier Leclerc · 1 janvier 2026

livraison rapide meme pendant les fetes je recommande

André Simon · 6 mars 2026

Correspond exactement à mes attentes

Jérémy Fontaine · 13 janvier 2026

RAS

63 VA · IP00—