← Three-Phase Transformers
IP23 · ventilated enclosure Three-phase transformer 230 V / 400 V + N in an IP23 ventilated enclosure

Three-phase transformer 230 V / 400 V + N

Step-up 3 × 230 V → 3 × 400 V + N · vector group Dyn11 · 1 to 100 kVA · made in France

5.0 · 1 review

16 kVA23.1 A per phase on the secondary

  • —
  • —
  • 5-year warranty · wound and tested in Gailhan

Key features

This three-phase transformer steps up a 3 × 230 V supply, often without a neutral, to 3 × 400 V + N: 400 V between phases and 230 V between each phase and neutral. It lets you connect standard European equipment — EV chargers, heat pumps, machine tools — where the supply is only 3 × 230 V, as in much of Belgium and Norway, or on an older 220 V three-phase installation. Vector group Dyn11, electrostatic shield as standard, 1 to 100 kVA in IP00, IP23 or IP54, and 125 to 1,000 kVA on request: it is wound and tested in our workshop in Gailhan (Gard, southern France).

Your supply3 × 230 Voften no neutral (formerly 220 V)
TransformerDyn11steps up and isolates
Your equipment3 × 400 V + N400 V between phases · 230 V phase to neutral
3 × 230 V → 3 × 400 V + NThe standard European supply, recreated from a 3 × 230 V network.
A true neutral230 V between each phase and neutral, for single-phase appliances.
Vector group Dyn11Delta primary, star secondary, neutral brought out to terminal 2N.
Galvanic isolationYour installation is electrically separated from the supply that feeds it.
Electrostatic shield as standardConnected to earth, it limits the transfer of disturbances between primary and secondary.
Made and tested in GailhanWound, wired and 100 % tested in our workshop in the Gard, southern France, before dispatch.
Single-phase 230 V to three-phase 400 V? You need a converter

This three-phase transformer steps up a three-phase voltage: it does not turn single-phase into three-phase. From a single-phase 230 V supply, you need a phase converter: tell us what you need.

22 kW EV charger on a 3 × 230 V supply

A 22 kW charger draws 3 × 32 A at 400 V + N: the 25 kVA model is suitable. On the supply side, allow for 62.8 A per phase at 230 V, protected by an 80 A type D circuit breaker.

230 V between phase and neutral

The secondary provides a true neutral: 230 V between it and each phase, as on a standard 400 V + N supply. Connected to earth, it gives a TN-S system.

When should you use a 230 V / 400 V three-phase transformer?

  • Installing an 11 or 22 kW EV charger (3 × 400 V + N) on a 3 × 230 V supply without a neutral.
  • Connecting a 400 V heat pump, air conditioning unit or compressor to a 3 × 230 V supply with a 230 V to 400 V transformer.
  • Running European 400 V machine tools, ovens or production lines on a 230 V site.
  • Creating a neutral and switching to a TN-S system on an older 220 V three-phase installation.

It works at 50 Hz, or at 60 Hz on confirmation. It is not suitable for 400 Hz supplies.

Specifications of the 230 V / 400 V + N three-phase transformer

Values for the selected configuration: 16 kVA · IP23.

Rating16 kVA50 Hz · Dyn11
Primary3 × 230 V Δno neutral
Secondary3 × 400 V YN230 V phase-neutral
ProtectionIP23ventilated enclosure
Primary
Phase-to-phase voltage
3 × 230 V
Connection
Delta (Δ)
Rated line current
40.2 A
Terminals
1U 1V 1W + PE
Secondary
Phase-to-phase voltage
3 × 400 V
Connection
Star with neutral (YN)
Rated line current
23.1 A
Phase-to-neutral voltage
230 V
Terminals
2U 2V 2W 2N + PE
Construction
Type
Dry-type transformer, natural cooling
Core
3 limbs, one coil per phase
Insulation class
H (180 °C)
Electrostatic shield
Fitted as standard, earthed
Standards
EN IEC 61558-1 and EN IEC 61558-2-4
Enclosure
IP rating
IP23, ventilated metal enclosure
Overall dimensions L × W × H
525 × 320 × 550 mm
Weight
131 kg
Mounting
2 feet, holes Ø 12 mm
Ambient temperature
40 °C maximum
Performancedesign values
Full-load efficiency97.3 %
No-load losses163 W
Load losses535 W
Full-load voltage drop2.1 %

Ratings and prices

From 1 to 100 kVA. Above that, on request.

A → recommended rating 25 kVA
RatingPrim. / sec. currentRecommended circuit breakerNo-load / load lossesEfficiencyWeightDimensions (mm)Price ex VATDispatch
1 kVA2.5 / 1.4 AD 4 A13 / 54 W93.7 %13 kg340 × 310 × 350€381.583 days
2 kVA5.0 / 2.9 AD 6 A22 / 106 W94.0 %20 kg340 × 310 × 350€430.753 days
2.5 kVA6.3 / 3.6 AD 10 A24 / 129 W94.2 %22 kg340 × 310 × 350€448.253 days
3.15 kVA7.9 / 4.5 AD 10 A30 / 141 W94.8 %26 kg340 × 310 × 350€467.423 days
4 kVA10.0 / 5.8 AD 16 A42 / 235 W93.5 %40 kg460 × 320 × 500€665.753 days
5 kVA12.6 / 7.2 AD 16 A51 / 264 W94.1 %46 kg460 × 320 × 500€694.923 days
6.3 kVA15.8 / 9.1 AD 20 A59 / 284 W94.8 %52 kg460 × 320 × 500€736.583 days
8 kVA20.1 / 11.5 AD 25 A90 / 264 W95.8 %75 kg525 × 335 × 550€1,031.583 days
10 kVA25.1 / 14.4 AD 32 A98 / 310 W96.1 %82 kg525 × 335 × 550€1,094.923 days
12 kVA30.1 / 17.3 AD 32 A114 / 358 W96.2 %92 kg525 × 335 × 550€1,425.753 days
16 kVA40.2 / 23.1 AD 50 A131 / 403 W96.8 %105 kg525 × 335 × 550€1,432.423 days
20 kVA50.2 / 28.9 AD 63 A147 / 523 W96.8 %116 kg525 × 335 × 550€1,514.923 days
25 kVA62.8 / 36.1 AD 80 A171 / 496 W97.4 %136 kg525 × 335 × 550€1,686.583 days
30 kVA75.3 / 43.3 AD 80 A134 / 668 W97.4 %119 kg700 × 480 × 720€1,854.083 days
40 kVA100.4 / 57.7 AD 125 A150 / 887 W97.5 %132 kg700 × 480 × 720€2,255.753 days
50 kVA125.5 / 72.2 AMCCB 160 A222 / 790 W98.0 %184 kg700 × 480 × 720€2,383.253 days
63 kVA158.1 / 90.9 AMCCB 200 A—*—*220 kg700 × 480 × 720€3,789.926 days
80 kVA200.8 / 115.5 AMCCB 250 A—*—*300 kg700 × 480 × 720€4,591.586 days
100 kVA251.0 / 144.3 AMCCB 315 A—*—*345 kg700 × 480 × 720€5,358.256 days
125 to 1,000 kVA
On request, in the standard ratings: 125, 160, 200, 250, 315, 400, 500, 630, 800 and 1,000 kVA. Request a quote

Rated currents: primary at 230 V / secondary at 400 V. Type D circuit breaker on the primary. Losses and efficiency: design values at full load. * 63 to 100 kVA: losses and efficiency on request. Prices exclude carriage. Calculator formula: kVA = √3 × 400 V × A ÷ 1,000 (current on the 400 V side), next standard rating up.

Wiring diagram and enclosure drawing

Extracts from the datasheet: coil-by-coil connections and enclosure dimensions.

Wiring diagram
PRIMARY · DELTA (Δ)U1U21U11UV1V21V11VW1W21W11W
COIL UCOIL VCOIL Wstart1U1end1U2start1V1end1V2start1W1end1W21U1V1W
SECONDARY · STAR WITH NEUTRAL (YN)U2U22U12UV2V22V12VW2W22W12W2N
COIL UCOIL VCOIL WNEUTRALstart2U1end2U2start2V1end2V2start2W1end2W2neutral2N2U2V2W2N
Enclosure IP23 · 25 kVA
ADGA1EBB1CØFØH
Technical document for the TTI230400N series
PDF · specifications, ratings and part numbers, protection
FRENDEESIT

Installation and protection

Values for 25 kVA. Sizing of the installation remains the installer's responsibility.

Upstream protection

Type D circuit breaker 40 A

or aM fuses 40 A · inrush current ≈ 433 A peak

Secondary neutral

  • Earthed: TN-S system, the most common.
  • Isolated from earth: IT system, with an insulation monitoring device.

Safety

  • Connection by a qualified person.
  • Earth connected before switching on.
  • IP00: in a cabinet or a closed electrical room.

Standards, warranty and options

A standard transformer, built to order and adaptable to your installation.

EN IEC 61558-2-4isolating transformers, with Part 1; above 40 kVA, by agreement
CE markingLow Voltage, EMC
RoHSfree of lead and restricted substances
5-year warrantyon our three-phase transformers
Made in FranceGailhan workshop (Gard, southern France)
Fast dispatch3 to 6 working days
Tappings±2.5 %, ±5 % or ±10 %
Other voltagesup to 1,000 V phase-to-phase
60 Hzon confirmation
Other vector groupsDd0, Yyn0, YNyn0, Yd11, YNd11
Temperature sensorsbimetallic, PTC or PT100
Forced ventilation230 V fans
Isolator switchhandle-operated, primary side
Castorsfor large enclosures

Frequently asked questions

About the 230 V / 400 V + N three-phase transformer.

Can this transformer convert single-phase 230 V to three-phase 400 V?

No: a three-phase transformer changes the voltage, not the number of phases. You need a 3 × 230 V three-phase supply to start with. From single-phase, you need a phase converter: tell us what you need and we will advise you.

How do I connect a 22 kW EV charger to a 3 × 230 V supply?

With the 25 kVA 230 V to 400 V transformer: the charger receives 3 × 400 V + N, as on a standard supply. On the primary, the transformer draws 62.8 A per phase at 230 V, with an 80 A type D circuit breaker; the rest of the installation is sized by your electrician.

220/380 V or 230/400 V: is it the same thing?

Yes: 220 V and 380 V are the former names for 230 V and 400 V. A “220 V three-phase” supply is a 3 × 230 V supply, so a 220 V to 400 V transformer, or “220 V / 380 V”, is this 230 V / 400 V three-phase transformer.

How do I wire a 230 V / 400 V three-phase transformer?

Primary connection: the supply goes to terminals 1U, 1V and 1W, earth to PE; the delta connection is made at the factory. On the secondary, the outgoing circuits leave from terminals 2U, 2V and 2W, and the neutral from terminal 2N. The full wiring diagram is on the datasheet.

Which rating should I choose?

To choose your 230 V / 400 V three-phase transformer, multiply the current per phase on the 400 V side by 400 V and by √3, then take the next standard rating up. For 40 A per phase: 27.7 kVA, so a 30 kVA unit. The calculator above the table does this for you.

Do you make three-phase transformers above 100 kVA?

Yes, on request: we also make this 230 V / 400 V three-phase transformer from 125 to 1,000 kVA, in the standard ratings 125, 160, 200, 250, 315, 400, 500, 630, 800 and 1,000 kVA. Choose the rating at the top of the page, below the priced ratings, or request a quote: reply within 48 h.

What upstream protection should I install?

On the 230 V side, the currents in the three-phase transformer are higher than on the 400 V side: for 16 kVA, 40.2 A per phase, i.e. a 50 A type D circuit breaker or 50 A aM fuses. The rating for each size is given in the table.

IP00, IP23 or IP54: which should I choose?

IP00: open-frame transformer, to be installed in a cabinet or a closed electrical room. IP23: ventilated enclosure, for a plant room sheltered from water. IP54: closed enclosure, protected against dust and splashing water.

What are the lead times?

From 1 to 50 kVA, dispatched from our workshop within 3 working days; from 63 to 100 kVA, within 6 working days. Up to 30 kg, the transformer ships as a parcel, with free delivery within France. Heavier units travel on a pallet with Kuehne + Nagel: 48 to 72 hours in mainland France, 96 hours elsewhere in Europe; pallet delivery is free from €1,000 ex VAT, otherwise a flat €50 ex VAT.