IP23 · ventilated enclosure Three-phase transformer 230 V / 230 V + N in an IP23 ventilated enclosure

Three-phase isolation transformer 230 V / 230 V + N

3 × 230 V isolation · creates a neutral · vector group Dyn11 · 1 to 100 kVA · made in France

No reviews of this model yet

5 kVA12.6 A per phase on the secondary

  • —
  • —
  • 5-year warranty · wound and tested in Gailhan

Key features

This three-phase transformer isolates your installation from a 3 × 230 V supply without changing the voltage, and gives it a neutral. On 3 × 230 V supplies without a neutral — IT systems in Belgium and Norway, older 220 V three-phase installations — it lets you switch to a TN-S system, with the neutral connected to earth, or create an isolated section with an insulation monitoring device. Vector group Dyn11, electrostatic shield as standard, 1 to 100 kVA in IP00, IP23 or IP54, and 125 to 1,000 kVA on request: it is wound and tested in our workshop in Gailhan (Gard, southern France).

Your supply3 × 230 Voften an IT system, no neutral
TransformerDyn11isolates, same voltage
Your installation3 × 230 V + Nneutral at 133 V, earthed or monitored
Galvanic isolationYour installation is electrically separated from the 3 × 230 V supply that feeds it.
Creates a neutralA neutral point at 133 V, for switching to TN-S or running a monitored IT section.
Vector group Dyn11Delta primary, star secondary, neutral brought out to terminal 2N.
Electrostatic shield as standardConnected to earth, it limits the transfer of disturbances between primary and secondary.
Voltage unchanged3 × 230 V in, 3 × 230 V out: your equipment sees no difference.
Made and tested in GailhanWound, wired and 100 % tested in our workshop in the Gard, southern France, before dispatch.
133 V between phase and neutral, not 230 V

On this three-phase transformer, the neutral is there for the earthing system, not for supplying single-phase 230 V appliances. To get 230 V between phase and neutral on a 3 × 230 V supply, choose the 230 V → 400 V + N model.

What it filters, and what it does not

The earthed shield limits the transfer of disturbances between the supply and your installation, and the delta primary winding traps the third harmonics generated by your loads. It does not correct low supply voltage or a power cut.

IT or TN-S: the installer's choice

Neutral connected to earth: TN-S system, protection by RCDs. Isolated neutral: IT system, which requires an insulation monitoring device. The 230 V to 230 V isolation transformer suits both.

When should you use a 230 V / 230 V three-phase transformer?

  • Converting a 3 × 230 V installation from an IT system to a TN-S system, so that it can be protected by RCDs.
  • Creating a monitored isolated section for equipment that must not trip on a first fault.
  • Shielding PLCs, CNC controls or laboratory equipment from supply disturbances.
  • Using a three-phase transformer to isolate the output of a 3 × 230 V generator or UPS from the installation it backs up.

It works at 50 Hz, or at 60 Hz on confirmation. It is not suitable for 400 Hz supplies.

Specifications of the 230 V / 230 V + N three-phase transformer

Values for the selected configuration: 5 kVA · IP23.

Rating5 kVA50 Hz · Dyn11
Primary3 × 230 V Δno neutral
Secondary3 × 230 V YN133 V phase-neutral
ProtectionIP23ventilated enclosure
Primary
Phase-to-phase voltage
3 × 230 V
Connection
Delta (Δ)
Rated line current
12.6 A
Terminals
1U 1V 1W + PE
Secondary
Phase-to-phase voltage
3 × 230 V
Connection
Star with neutral (YN)
Rated line current
12.6 A
Phase-to-neutral voltage
133 V
Terminals
2U 2V 2W 2N + PE
Construction
Type
Dry-type transformer, natural cooling
Core
3 limbs, one coil per phase
Insulation class
H (180 °C)
Electrostatic shield
Fitted as standard, earthed
Standards
EN IEC 61558-1 and EN IEC 61558-2-4
Enclosure
IP rating
IP23, ventilated metal enclosure
Overall dimensions L × W × H
525 × 320 × 550 mm
Weight
131 kg
Mounting
2 feet, holes Ø 12 mm
Ambient temperature
40 °C maximum
Performancedesign values
Full-load efficiency97.3 %
No-load losses163 W
Load losses535 W
Full-load voltage drop2.1 %

Ratings and prices

From 1 to 100 kVA. Above that, on request.

A → recommended rating 25 kVA
RatingCurrentRecommended circuit breakerNo-load / load lossesEfficiencyWeightDimensions (mm)Price ex VATDispatch
1 kVA2.5 AD 4 A12 / 58 W93.4 %12 kg340 × 310 × 350€381.583 days
2 kVA5.0 AD 6 A22 / 107 W93.9 %20 kg340 × 310 × 350€430.753 days
2.5 kVA6.3 AD 10 A24 / 130 W94.2 %22 kg340 × 310 × 350€448.253 days
3.15 kVA7.9 AD 10 A30 / 143 W94.8 %26 kg340 × 310 × 350€467.423 days
4 kVA10.0 AD 16 A42 / 240 W93.4 %40 kg460 × 320 × 500€665.753 days
5 kVA12.6 AD 16 A51 / 261 W94.1 %46 kg460 × 320 × 500€694.923 days
6.3 kVA15.8 AD 20 A59 / 281 W94.9 %52 kg460 × 320 × 500€736.583 days
8 kVA20.1 AD 25 A90 / 281 W95.6 %74 kg525 × 335 × 550€1,031.583 days
10 kVA25.1 AD 32 A98 / 322 W96.0 %81 kg525 × 335 × 550€1,094.923 days
12 kVA30.1 AD 32 A114 / 353 W96.3 %92 kg525 × 335 × 550€1,425.753 days
16 kVA40.2 AD 50 A131 / 412 W96.7 %105 kg525 × 335 × 550€1,432.423 days
20 kVA50.2 AD 63 A147 / 518 W96.8 %116 kg525 × 335 × 550€1,514.923 days
25 kVA62.8 AD 80 A155 / 574 W97.2 %126 kg525 × 335 × 550€1,686.583 days
30 kVA75.3 AD 80 A134 / 621 W97.5 %120 kg700 × 480 × 720€1,854.083 days
40 kVA100.4 AD 125 A150 / 882 W97.5 %132 kg700 × 480 × 720€2,255.753 days
50 kVA125.5 AMCCB 160 A206 / 892 W97.9 %173 kg700 × 480 × 720€2,383.253 days
63 kVA158.1 AMCCB 200 A—*—*220 kg700 × 480 × 720€3,789.926 days
80 kVA200.8 AMCCB 250 A—*—*300 kg700 × 480 × 720€4,591.586 days
100 kVA251.0 AMCCB 315 A—*—*345 kg700 × 480 × 720€5,358.256 days
125 to 1,000 kVA
On request, in the standard ratings: 125, 160, 200, 250, 315, 400, 500, 630, 800 and 1,000 kVA. Request a quote

Rated current: primary = secondary (1:1 ratio). Type D circuit breaker on the primary. Losses and efficiency: design values at full load. * 63 to 100 kVA: losses and efficiency on request. Prices exclude carriage. Calculator formula: kVA = √3 × 230 V × A ÷ 1,000 (current on the 230 V side), next standard rating up.

Wiring diagram and enclosure drawing

Extracts from the datasheet: coil-by-coil connections and enclosure dimensions.

Wiring diagram
PRIMARY · DELTA (Δ)U1U21U11UV1V21V11VW1W21W11W
COIL UCOIL VCOIL Wstart1U1end1U2start1V1end1V2start1W1end1W21U1V1W
SECONDARY · STAR WITH NEUTRAL (YN)U2U22U12UV2V22V12VW2W22W12W2N
COIL UCOIL VCOIL WNEUTRALstart2U1end2U2start2V1end2V2start2W1end2W2neutral2N2U2V2W2N
Enclosure IP23 · 25 kVA
ADGA1EBB1CØFØH
Technical document for the TTI230230N series
PDF · specifications, ratings and part numbers, protection
FRENDEESIT

Installation and protection

Values for 25 kVA. Sizing of the installation remains the installer's responsibility.

Upstream protection

Type D circuit breaker 40 A

or aM fuses 40 A · inrush current ≈ 433 A peak

Secondary neutral

  • Earthed: TN-S system, the most common.
  • Isolated from earth: IT system, with an insulation monitoring device.

Safety

  • Connection by a qualified person.
  • Earth connected before switching on.
  • IP00: in a cabinet or a closed electrical room.

Standards, warranty and options

A standard transformer, built to order and adaptable to your installation.

EN IEC 61558-2-4isolating transformers, with Part 1; above 40 kVA, by agreement
CE markingLow Voltage, EMC
RoHSfree of lead and restricted substances
5-year warrantyon our three-phase transformers
Made in FranceGailhan workshop (Gard, southern France)
Fast dispatch3 to 6 working days
Tappings±2.5 %, ±5 % or ±10 %
Other voltagesup to 1,000 V phase-to-phase
60 Hzon confirmation
Other vector groupsDd0, Yyn0, YNyn0, Yd11, YNd11
Temperature sensorsbimetallic, PTC or PT100
Forced ventilation230 V fans
Isolator switchhandle-operated, primary side
Castorsfor large enclosures

Frequently asked questions

About the 230 V / 230 V + N three-phase isolation transformer.

Why use a 230 V / 230 V three-phase transformer if the voltage stays the same?

To isolate: the secondary no longer has any electrical connection to the supply, and you choose its earthing system (TN-S or IT) independently of the network operator's. It is also a barrier against disturbances.

Can I get 230 V between phase and neutral?

No: on this model, the neutral is at 133 V from the phases. For 230 V between phase and neutral from a 3 × 230 V supply, choose the 230 V → 400 V + N model.

How do I convert from an IT system to TN-S?

By connecting the secondary neutral (terminal 2N) to earth at the transformer, then protecting the outgoing circuits with RCDs. The system design is your electrician's responsibility.

How do I wire a 230 V / 230 V three-phase transformer?

Primary connection: the supply goes to terminals 1U, 1V and 1W, earth to PE; the delta connection is made at the factory. On the secondary, the outgoing circuits leave from terminals 2U, 2V and 2W, and the neutral from terminal 2N. The full wiring diagram is on the datasheet.

Which rating should I choose?

To choose your 230 V / 230 V three-phase transformer, multiply the current per phase on the 230 V side by 230 V and by √3, then take the next standard rating up. For 32 A per phase: 12.7 kVA, so a 16 kVA unit. The calculator above the table does this for you.

Do you make three-phase transformers above 100 kVA?

Yes, on request: we also make this 230 V / 230 V three-phase transformer from 125 to 1,000 kVA, in the standard ratings 125, 160, 200, 250, 315, 400, 500, 630, 800 and 1,000 kVA. Choose the rating at the top of the page, below the priced ratings, or request a quote: reply within 48 h.

What upstream protection should I install?

On the primary (230 V) of your 230 V / 230 V three-phase transformer, a type D circuit breaker or aM fuses sized for the rated current: for 5 kVA, 12.6 A per phase, i.e. a 16 A type D circuit breaker or 16 A aM fuses. At switch-on, the inrush current reaches about twelve times the rated current; the rating for each size is given in the table.

IP00, IP23 or IP54: which should I choose?

IP00: open-frame transformer, to be installed in a cabinet or a closed electrical room. IP23: ventilated enclosure, for a plant room sheltered from water. IP54: closed enclosure, protected against dust and splashing water.

What are the lead times?

From 1 to 50 kVA, dispatched from our workshop within 3 working days; from 63 to 100 kVA, within 6 working days. Up to 30 kg, the transformer ships as a parcel, with free delivery within France. Heavier units travel on a pallet with Kuehne + Nagel: 48 to 72 hours in mainland France, 96 hours elsewhere in Europe; pallet delivery is free from €1,000 ex VAT, otherwise a flat €50 ex VAT.

Customer reviews

No reviews of this model yet. Here is what customers say about another three-phase transformer built the same way (reviews in French).

Julien Moretti · 2 octobre 2025 · sur le 400 V / 400 V + N

Livraison rapide, produit conforme et bien emballé. Installation sans difficulté, parfait pour créer un neutre. Le service téléphonique est top, fabrication française en plus. Je recommande sans hésiter.

Martin Delmas · 21 septembre 2025 · sur le 400 V / 400 V + N

Produit reçu rapidement, très bien emballé. Fonctionne parfaitement sur notre installation industrielle. Fabrication sérieuse, rien à signaler après plusieurs semaines d'utilisation. Content d'acheter français.

Mickaël Dupuy · 3 juin 2025 · sur le 400 V / 400 V + N

Produit conforme à la description, fabrication robuste et délai respecté. Service client à l’écoute, installation réalisée sans souci. Très satisfait de la qualité, matériel professionnel, rien à dire de plus.

5 kVA · IP23—